Cyclam-functionalized silica-modified electrodes for selective determination of Cu(II)
2009
Cyclam derivatives have been grafted via 1, 2 or 4 silylated arms to the surface of mesoporous silica and the resulting materials have been incorporated into carbon paste electrodes and applied to the preconcentration electroanalysis of Cu(II). Sensitive and selective detection of the target analyte was achieved owing to the attractive binding properties of this macrocyclic ligand towards Cu(II) species. Various parameters likely to affect the preconcentration and detection steps have been studied, including pH of the accumulation medium, composition of the detection solution, structure and composition of the adsorbent, accumulation time, or presence of potentially interfering species. In p…
Simultaneous homogeneous immunoassay of phenytoin and phenobarbital using a Nafion-loaded carbon paste electrode and two redox cationic labels
1997
Abstract The dual-analyte homogeneous immunoassay of two antiepileptic drugs was carried out simultaneously at physiological pH by square-wave voltammetry at a Nafion-loaded carbon paste electrode. Phenobarbital (PB) and phenytoin (DPH) were labeled by a cobaltocenium salt (Cc+) and a ferroceneammonium salt (N+Fc), respectively, and the corresponding standard redox potentials were −1.05 V and 0.26 V. Detection limits of 0.25 and 0.2 μM were achieved for PB-Cc+ and DPH-N+Fc (S/N = 3) after a 5-minute accumulation step, with linear responses over the 0.25–5 and 0.2–5 μM ranges, respectively. The relative standard deviation was evaluated to be ≥ 11% for 1 μM of each labeled drug. The separate,…
Adsorption enrichment of some azo dye complexes on a carbon paste electrode and its application to the determination of small concentrations of cobal…
1974
The azo dyes eriochrome black T, eriochrome blueblack R and eriochrome blueblack B and their complexes with cobalt, manganese and magnesium show adsorption enrichment on carbon paste electrodes, dependent on the composition of the electrode filling. This effect may be used for the determination of cobalt and manganese by a.c. voltammetry in the 10−7 to 10−6 M range. Standard deviation has been found to be ± 3.2 and ± 3.5%, respectively.
Voltammetric Detection of Lead(II) Using Amide-Cyclam- Functionalized Silica-Modified Carbon Paste Electrodes
2009
2-(4,8,11-Triscarbamoylmethyl-1,4,8,11-tetraazacyclotetradec-1-yl)acetamide (TETAM) derivatives bearing 1, 2, or 4 silylated arms have been synthesized and grafted to the surface of silica gel and ordered mesoporous silica samples. The resulting organic-inorganic hybrids have been incorporated into carbon paste electrodes and applied to the preconcentration electroanalysis of Pb(II). The attractive recognition properties of these cyclam derivatives functionalized with amide pendent groups toward Pb(II) species and the highly porous structure of the adsorbents can be exploited for the selective and sensitive detection of the target analyte. Various parameters affecting the preconcentration a…